Home›Free tools›Appliance wattage chart

Free referenceAppliance wattage chart

Running watts and starting watts for 68 household, RV, medical and workshop appliances, from published sources. Tick what you want to run and see the size of power station it takes.

  • 68appliances
  • 6published sources
  • 2figures per appliance: running and starting
68 of 68 appliancesTick an appliance to add it to your list.

Your list

Tick the appliances you want to run. The chart adds up the running watts, the starting peak and the energy for a day, then points you to the power stations that can handle it.

Running and starting watts of 68 appliances
Add to your listApplianceRunning wattsStarting wattsExample dayour assumptionPower stations
Kitchen
Refrigerator or freezer, Energy StarThe compressor cycles on and off. Our example counts 8 hours of run time a day.132 to 192 W1,200 W1.3 kWh8 h a day
Refrigerator or freezer, older modelThe figure utility generator guides still use. DTE lists 750 W with a starting factor of 3.700 to 750 W2,200 W5.6 kWh8 h a day
Microwave, 650 W cooking powerA microwave draws more from the outlet than its cooking power.1,000 WSame as running250 Wh15 min a day
Microwave, 1,000 W cooking power1,500 WSame as running375 Wh15 min a day
Coffee makerHonda lists 600 W for a 4-cup model, EWEB 1,000 W for a full-size one.600 to 1,200 WSame as running250 Wh15 min a day
Toaster850 to 1,100 WSame as running90 Wh6 min a day
Toaster oven1,200 WSame as running600 Wh30 min a day
DishwasherHonda lists 216 W running on a cool-dry cycle. The heating element is what takes it to 1,200 W.216 to 1,200 W540 to 2,400 W1.2 kWh1 h a day
Electric fry pan1,500 WSame as running750 Wh30 min a day
Electric range, 8-inch elementDTE lists 1,300 W for a small burner and 2,400 W for a large one.240 V appliance2,100 WSame as running1.1 kWh30 min a dayNeeds a 240 V station
Slow cooker170 to 270 WSame as running1.3 kWh6 h a day
Blender400 W850 W40 Wh6 min a day
Electric grill, tabletop1,650 WSame as running825 Wh30 min a day
Air fryer1,500 WSame as running750 Wh30 min a day
Electric kettleA common US label rating. Check the base of yours.Our estimate1,500 WSame as running150 Wh6 min a day
Home and comfort
Window air conditioner, 10,000 BTU1,500 W2,200 W12 kWh8 h a day
Furnace fan, 1/3 hpFor a gas or oil furnace: the blower is the electrical load.700 W1,400 W5.6 kWh8 h a day
Furnace fan, 1/2 hp875 W2,350 W7.0 kWh8 h a day
Space heater1,500 W on high, the usual maximum for a 120 V heater.500 to 1,500 WSame as running6.0 kWh4 h a day
Portable fan40 W120 W320 Wh8 h a day
Sump pump, 1/3 hp800 W1,300 W800 Wh1 h a day
Sump pump, 1/2 hpEWEB lists 2,200 W to start.1,050 W2,150 W1.1 kWh1 h a day
Well pump, 1/3 hp750 to 1,000 W2,000 to 2,250 W1.0 kWh1 h a day
Electric water heater240 V appliance4,500 WSame as running14 kWh3 h a dayNeeds a 240 V station
Washing machine1,000 to 1,200 W1,200 to 2,000 W1.2 kWh1 h a day
Clothes dryer, electric240 V appliance5,400 W6,750 W5.4 kWh1 h a dayNeeds a 240 V station
Garage door openerIt runs for seconds at a time, so the starting figure is the one that matters.720 W1,420 W36 Wh3 min a day
Hair dryer, 1,600 W1,800 W1,900 W360 Wh12 min a day
Dehumidifier840 W1,680 W6.7 kWh8 h a day
Vacuum cleaner800 WSame as running240 Wh18 min a day
Incandescent bulb, 60 W60 WSame as running300 Wh5 h a day
LED bulb15 WSame as running75 Wh5 h a day
Humidifier177 WSame as running1.4 kWh8 h a day
Air cleaner50 W100 W600 Wh12 h a day
Central air conditioner, 3 tonOut of reach for a single portable power station.240 V appliance6,000 W18,000 W48 kWh8 h a dayNeeds a 240 V station
Electronics
LED TV80 WSame as running320 Wh4 h a day
Older flat-screen TVHonda's figures for LCD-era sets: 120 W for a 20-inch, 190 W for a 46-inch.120 to 190 WSame as running760 Wh4 h a day
LaptopA charger pulls less once the battery is full. Honda's older guide lists 200 to 250 W, closer to a gaming laptop under load.Can run on USB-C or 12 V60 WSame as running240 Wh4 h a day
Desktop computer with monitorThe widest spread in this chart: 200 W at DTE, 600 to 800 W at Honda and EWEB.200 to 800 WSame as running800 Wh4 h a day
LCD monitor30 WSame as running120 Wh4 h a day
Printer400 to 600 WSame as running100 Wh12 min a day
Phone chargerCan run on USB-C or 12 V20 WSame as running40 Wh2 h a day
Radio50 to 200 WSame as running400 Wh4 h a day
Satellite receiver250 WSame as running1.0 kWh4 h a day
Wi-Fi routerRead the power adapter: volts times amps gives the ceiling.Our estimate10 to 20 WSame as running360 Wh24 h a day
Home security system200 WSame as running4.8 kWh24 h a day
Medical
CPAP, no humidifierResMed bench figures for AirSense 10 and AirCurve 10. Your pressure setting changes the draw.Can run on USB-C or 12 V7 to 10 WSame as running80 Wh8 h a day
CPAP with humidifier22 to 27 WSame as running216 Wh8 h a day
CPAP with humidifier and heated tube34 to 44 WSame as running352 Wh8 h a day
Tools
Circular saw, 7-1/4 in1,400 W2,300 W700 Wh30 min a day
Drill, 3/8 in440 W600 W220 Wh30 min a day
Drill, 1/2 in600 W900 W300 Wh30 min a day
Table saw, 10 in1,800 W4,500 W900 Wh30 min a day
Air compressor, 1/2 hp975 W1,600 W488 Wh30 min a day
Air compressor, 1 hp1,600 W4,500 W800 Wh30 min a day
Bench grinder, 8 in1,400 W2,500 W700 Wh30 min a day
Pressure washer, 1 hp1,200 W3,600 W600 Wh30 min a day
Electric chain saw, 14 in1,100 WSame as running550 Wh30 min a day
Battery charger, 15 amp380 WSame as running1.1 kWh3 h a day
Rotary hammer1,200 WSame as running600 Wh30 min a day
Camping and RV
RV air conditioner, 11,000 BTU1,010 W1,600 W6.1 kWh6 h a day
RV air conditioner, 13,500 BTU1,800 W2,800 W11 kWh6 h a day
RV air conditioner, 15,000 BTU2,000 W3,300 W12 kWh6 h a day
RV refrigerator180 W600 W1.4 kWh8 h a day
Electric coolerCan run on USB-C or 12 V50 WSame as running600 Wh12 h a day
12V compressor fridgeWhile the compressor runs. The figure our comparison chart uses.Can run on USB-C or 12 VOur estimate45 WSame as running360 Wh8 h a day

No appliance matches.

Running watts and starting watts

Two figures decide whether a power source can run an appliance. A third decides for how long.

While it works

Running watts

The steady draw once the appliance is on. Add up the running watts of everything you use at the same time: the total has to fit under the output of your power station.

For a second or two

Starting watts

Motors and compressors need a short burst to get moving. An Energy Star fridge runs at 132 to 192 W but asks for about 1,200 W to start. Count the largest burst once, on top of the running total.

Over a day

Watt-hours

Watts times hours gives energy. A 1,500 W heater used for 4 hours takes 6.0 kWh. This is the figure to compare with the capacity of a battery.

How to find the wattage of your own appliance

The chart gives typical figures. Yours is printed on the appliance.

  1. Read the nameplateLook for a label on the back, the base or inside the door. It lists watts (W), or volts (V) and amps (A).
  2. Multiply if neededVolts times amps gives watts. An appliance marked 120 V and 5 A draws up to 600 W. The label shows the maximum, so real use is often lower.
  3. Measure for certaintyA plug-in watt meter between the outlet and the appliance shows the real draw, including the peak when a motor starts.

From watts to a power station

Three checks, in this order.

Check 1

Output

The station’s rated AC output must be at least your running total. A 1,500 W heater will not run on a 1,000 W station, whatever the battery size.

Check 2

Surge

The surge rating must cover the starting peak. This is the check that catches fridges, pumps and power tools.

Check 3

Capacity

About 85% of the battery reaches your appliances after conversion losses. Divide the energy you need by 0.85 to get the capacity to look for.

Capacity needed (Wh) = watts × hours ÷ 0.85Then compare models in the power station comparison chart or size a full setup in the runtime calculator. Adding solar? See the solar panel comparison chart. Powering a dish? Try the Starlink power calculator.

Questions about appliance wattage

How many watts does a refrigerator use?

Honda's wattage guide lists an Energy Star refrigerator or freezer at 132 to 192 W while the compressor runs, and about 1,200 W for the instant it starts. Older generator guides from utilities still use 700 W running and 2,200 W starting, which fits a much older fridge. The compressor does not run all day, so daily energy is far lower than running watts times 24.

What is the difference between running watts and starting watts?

Running watts are what an appliance draws once it is working. Starting watts are the brief peak a motor or compressor needs to get moving. Heaters, toasters and electronics have no such peak, which is why the chart shows the same figure for both. To size a power source, add the running watts of everything that is on together, then add the largest single starting peak.

How many watts does a microwave use?

More than the number on the door. Honda lists 1,000 W of draw for a 650 W microwave and 1,500 W for a 1,000 W one. The door figure is cooking power, and the outlet has to supply the losses too.

Can a portable power station run a space heater?

Yes, if its AC output is at least the heater's draw, which is 1,500 W on high for most 120 V models. The limit is the battery: a 1,000 Wh station delivers about 850 Wh, so 1,500 W lasts roughly 34 minutes. A low setting stretches that.

How many watts does a CPAP machine use?

ResMed's bench figures for its Air10 machines are 7 to 10 W with no humidifier, 22 to 27 W with the humidifier, and 34 to 44 W with the humidifier and a heated tube. The humidifier is what multiplies the draw, so switching it off is the simplest way to gain nights on a battery.

How many watts does Starlink use?

Starlink gives an average of 75 to 100 W for the Standard kit and 20 to 40 W for the Mini, router and power supply included. Both draw less when idle.

How do I work out what size power station I need?

Tick your appliances in the chart and set how many hours each one runs. The list adds up three figures: running watts, starting peak and energy for a day. Pick a station whose output covers the first, whose surge rating covers the second, and whose capacity covers the third divided by 0.85.

Sources and method

  • The figures come from the six published sources above. Where they disagree, the chart shows the range and the note under the appliance says who gives what.
  • Starting watts are the total draw at start-up as published by the source. For the DTE guide, which gives a starting factor, the chart multiplies running watts by that factor.
  • 3 figures are our own estimate and are marked as such: electric kettle, wi-fi router, 12v compressor fridge.
  • The example day is our assumption of typical use, not a measurement. Change the hours in your list to match your own.
  • The stations shown under an appliance come from our comparison chart: those in stock whose rated output and surge cover the appliance, lowest price first.
  • These are reference values. The nameplate of your appliance, or a watt meter, always wins.

Sources read on November 16, 2026.