Home›Free tools›Appliance wattage chart
Free referenceAppliance wattage chart
Running watts and starting watts for 68 household, RV, medical and workshop appliances, from published sources. Tick what you want to run and see the size of power station it takes.
- 68appliances
- 6published sources
- 2figures per appliance: running and starting
Your list
Tick the appliances you want to run. The chart adds up the running watts, the starting peak and the energy for a day, then points you to the power stations that can handle it.
| Appliance | Running watts | Starting watts | Example dayour assumption | ||
|---|---|---|---|---|---|
| Kitchen | |||||
| Refrigerator or freezer, Energy StarThe compressor cycles on and off. Our example counts 8 hours of run time a day. | 132 to 192 W | 1,200 W | 1.3 kWh8 h a day | ||
| Refrigerator or freezer, older modelThe figure utility generator guides still use. DTE lists 750 W with a starting factor of 3. | 700 to 750 W | 2,200 W | 5.6 kWh8 h a day | ||
| Microwave, 650 W cooking powerA microwave draws more from the outlet than its cooking power. | 1,000 W | Same as running | 250 Wh15 min a day | ||
| Microwave, 1,000 W cooking power | 1,500 W | Same as running | 375 Wh15 min a day | ||
| Coffee makerHonda lists 600 W for a 4-cup model, EWEB 1,000 W for a full-size one. | 600 to 1,200 W | Same as running | 250 Wh15 min a day | ||
| Toaster | 850 to 1,100 W | Same as running | 90 Wh6 min a day | ||
| Toaster oven | 1,200 W | Same as running | 600 Wh30 min a day | ||
| DishwasherHonda lists 216 W running on a cool-dry cycle. The heating element is what takes it to 1,200 W. | 216 to 1,200 W | 540 to 2,400 W | 1.2 kWh1 h a day | ||
| Electric fry pan | 1,500 W | Same as running | 750 Wh30 min a day | ||
| Electric range, 8-inch elementDTE lists 1,300 W for a small burner and 2,400 W for a large one.240 V appliance | 2,100 W | Same as running | 1.1 kWh30 min a day | Needs a 240 V station | |
| Slow cooker | 170 to 270 W | Same as running | 1.3 kWh6 h a day | ||
| Blender | 400 W | 850 W | 40 Wh6 min a day | ||
| Electric grill, tabletop | 1,650 W | Same as running | 825 Wh30 min a day | ||
| Air fryer | 1,500 W | Same as running | 750 Wh30 min a day | ||
| Electric kettleA common US label rating. Check the base of yours.Our estimate | 1,500 W | Same as running | 150 Wh6 min a day | ||
| Home and comfort | |||||
| Window air conditioner, 10,000 BTU | 1,500 W | 2,200 W | 12 kWh8 h a day | ||
| Furnace fan, 1/3 hpFor a gas or oil furnace: the blower is the electrical load. | 700 W | 1,400 W | 5.6 kWh8 h a day | ||
| Furnace fan, 1/2 hp | 875 W | 2,350 W | 7.0 kWh8 h a day | ||
| Space heater1,500 W on high, the usual maximum for a 120 V heater. | 500 to 1,500 W | Same as running | 6.0 kWh4 h a day | ||
| Portable fan | 40 W | 120 W | 320 Wh8 h a day | ||
| Sump pump, 1/3 hp | 800 W | 1,300 W | 800 Wh1 h a day | ||
| Sump pump, 1/2 hpEWEB lists 2,200 W to start. | 1,050 W | 2,150 W | 1.1 kWh1 h a day | ||
| Well pump, 1/3 hp | 750 to 1,000 W | 2,000 to 2,250 W | 1.0 kWh1 h a day | ||
| Electric water heater240 V appliance | 4,500 W | Same as running | 14 kWh3 h a day | Needs a 240 V station | |
| Washing machine | 1,000 to 1,200 W | 1,200 to 2,000 W | 1.2 kWh1 h a day | ||
| Clothes dryer, electric240 V appliance | 5,400 W | 6,750 W | 5.4 kWh1 h a day | Needs a 240 V station | |
| Garage door openerIt runs for seconds at a time, so the starting figure is the one that matters. | 720 W | 1,420 W | 36 Wh3 min a day | ||
| Hair dryer, 1,600 W | 1,800 W | 1,900 W | 360 Wh12 min a day | ||
| Dehumidifier | 840 W | 1,680 W | 6.7 kWh8 h a day | ||
| Vacuum cleaner | 800 W | Same as running | 240 Wh18 min a day | ||
| Incandescent bulb, 60 W | 60 W | Same as running | 300 Wh5 h a day | ||
| LED bulb | 15 W | Same as running | 75 Wh5 h a day | ||
| Humidifier | 177 W | Same as running | 1.4 kWh8 h a day | ||
| Air cleaner | 50 W | 100 W | 600 Wh12 h a day | ||
| Central air conditioner, 3 tonOut of reach for a single portable power station.240 V appliance | 6,000 W | 18,000 W | 48 kWh8 h a day | Needs a 240 V station | |
| Electronics | |||||
| LED TV | 80 W | Same as running | 320 Wh4 h a day | ||
| Older flat-screen TVHonda's figures for LCD-era sets: 120 W for a 20-inch, 190 W for a 46-inch. | 120 to 190 W | Same as running | 760 Wh4 h a day | ||
| LaptopA charger pulls less once the battery is full. Honda's older guide lists 200 to 250 W, closer to a gaming laptop under load.Can run on USB-C or 12 V | 60 W | Same as running | 240 Wh4 h a day | ||
| Desktop computer with monitorThe widest spread in this chart: 200 W at DTE, 600 to 800 W at Honda and EWEB. | 200 to 800 W | Same as running | 800 Wh4 h a day | ||
| LCD monitor | 30 W | Same as running | 120 Wh4 h a day | ||
| Printer | 400 to 600 W | Same as running | 100 Wh12 min a day | ||
| Phone chargerCan run on USB-C or 12 V | 20 W | Same as running | 40 Wh2 h a day | ||
| Radio | 50 to 200 W | Same as running | 400 Wh4 h a day | ||
| Satellite receiver | 250 W | Same as running | 1.0 kWh4 h a day | ||
| Wi-Fi routerRead the power adapter: volts times amps gives the ceiling.Our estimate | 10 to 20 W | Same as running | 360 Wh24 h a day | ||
| Starlink StandardAverage draw, router and power supply included. About 20 W when idle. | 75 to 100 W | Same as running | 2.4 kWh24 h a day | ||
| Starlink MiniAverage draw. About 15 W when idle.Can run on USB-C or 12 V | 20 to 40 W | Same as running | 960 Wh24 h a day | ||
| Home security system | 200 W | Same as running | 4.8 kWh24 h a day | ||
| Medical | |||||
| CPAP, no humidifierResMed bench figures for AirSense 10 and AirCurve 10. Your pressure setting changes the draw.Can run on USB-C or 12 V | 7 to 10 W | Same as running | 80 Wh8 h a day | ||
| CPAP with humidifier | 22 to 27 W | Same as running | 216 Wh8 h a day | ||
| CPAP with humidifier and heated tube | 34 to 44 W | Same as running | 352 Wh8 h a day | ||
| Tools | |||||
| Circular saw, 7-1/4 in | 1,400 W | 2,300 W | 700 Wh30 min a day | ||
| Drill, 3/8 in | 440 W | 600 W | 220 Wh30 min a day | ||
| Drill, 1/2 in | 600 W | 900 W | 300 Wh30 min a day | ||
| Table saw, 10 in | 1,800 W | 4,500 W | 900 Wh30 min a day | ||
| Air compressor, 1/2 hp | 975 W | 1,600 W | 488 Wh30 min a day | ||
| Air compressor, 1 hp | 1,600 W | 4,500 W | 800 Wh30 min a day | ||
| Bench grinder, 8 in | 1,400 W | 2,500 W | 700 Wh30 min a day | ||
| Pressure washer, 1 hp | 1,200 W | 3,600 W | 600 Wh30 min a day | ||
| Electric chain saw, 14 in | 1,100 W | Same as running | 550 Wh30 min a day | ||
| Battery charger, 15 amp | 380 W | Same as running | 1.1 kWh3 h a day | ||
| Rotary hammer | 1,200 W | Same as running | 600 Wh30 min a day | ||
| Camping and RV | |||||
| RV air conditioner, 11,000 BTU | 1,010 W | 1,600 W | 6.1 kWh6 h a day | ||
| RV air conditioner, 13,500 BTU | 1,800 W | 2,800 W | 11 kWh6 h a day | ||
| RV air conditioner, 15,000 BTU | 2,000 W | 3,300 W | 12 kWh6 h a day | ||
| RV refrigerator | 180 W | 600 W | 1.4 kWh8 h a day | ||
| Electric coolerCan run on USB-C or 12 V | 50 W | Same as running | 600 Wh12 h a day | ||
| 12V compressor fridgeWhile the compressor runs. The figure our comparison chart uses.Can run on USB-C or 12 VOur estimate | 45 W | Same as running | 360 Wh8 h a day | ||
No appliance matches.
Running watts and starting watts
Two figures decide whether a power source can run an appliance. A third decides for how long.
Running watts
The steady draw once the appliance is on. Add up the running watts of everything you use at the same time: the total has to fit under the output of your power station.
Starting watts
Motors and compressors need a short burst to get moving. An Energy Star fridge runs at 132 to 192 W but asks for about 1,200 W to start. Count the largest burst once, on top of the running total.
Watt-hours
Watts times hours gives energy. A 1,500 W heater used for 4 hours takes 6.0 kWh. This is the figure to compare with the capacity of a battery.
How to find the wattage of your own appliance
The chart gives typical figures. Yours is printed on the appliance.
- Read the nameplateLook for a label on the back, the base or inside the door. It lists watts (W), or volts (V) and amps (A).
- Multiply if neededVolts times amps gives watts. An appliance marked 120 V and 5 A draws up to 600 W. The label shows the maximum, so real use is often lower.
- Measure for certaintyA plug-in watt meter between the outlet and the appliance shows the real draw, including the peak when a motor starts.
From watts to a power station
Three checks, in this order.
Output
The station’s rated AC output must be at least your running total. A 1,500 W heater will not run on a 1,000 W station, whatever the battery size.
Surge
The surge rating must cover the starting peak. This is the check that catches fridges, pumps and power tools.
Capacity
About 85% of the battery reaches your appliances after conversion losses. Divide the energy you need by 0.85 to get the capacity to look for.
Questions about appliance wattage
How many watts does a refrigerator use?
Honda's wattage guide lists an Energy Star refrigerator or freezer at 132 to 192 W while the compressor runs, and about 1,200 W for the instant it starts. Older generator guides from utilities still use 700 W running and 2,200 W starting, which fits a much older fridge. The compressor does not run all day, so daily energy is far lower than running watts times 24.
What is the difference between running watts and starting watts?
Running watts are what an appliance draws once it is working. Starting watts are the brief peak a motor or compressor needs to get moving. Heaters, toasters and electronics have no such peak, which is why the chart shows the same figure for both. To size a power source, add the running watts of everything that is on together, then add the largest single starting peak.
How many watts does a microwave use?
More than the number on the door. Honda lists 1,000 W of draw for a 650 W microwave and 1,500 W for a 1,000 W one. The door figure is cooking power, and the outlet has to supply the losses too.
Can a portable power station run a space heater?
Yes, if its AC output is at least the heater's draw, which is 1,500 W on high for most 120 V models. The limit is the battery: a 1,000 Wh station delivers about 850 Wh, so 1,500 W lasts roughly 34 minutes. A low setting stretches that.
How many watts does a CPAP machine use?
ResMed's bench figures for its Air10 machines are 7 to 10 W with no humidifier, 22 to 27 W with the humidifier, and 34 to 44 W with the humidifier and a heated tube. The humidifier is what multiplies the draw, so switching it off is the simplest way to gain nights on a battery.
How many watts does Starlink use?
Starlink gives an average of 75 to 100 W for the Standard kit and 20 to 40 W for the Mini, router and power supply included. Both draw less when idle.
How do I work out what size power station I need?
Tick your appliances in the chart and set how many hours each one runs. The list adds up three figures: running watts, starting peak and energy for a day. Pick a station whose output covers the first, whose surge rating covers the second, and whose capacity covers the third divided by 0.85.
Sources and method
- Honda Power Equipment: Wattage estimation guide
- EWEB (Eugene Water and Electric Board): Generator sizing considerations, reference guide
- DTE Energy: Appliance usage guide (GenerLink worksheet)
- Champion Power Equipment: Quick reference wattage flyer
- Starlink: Help center: how much power does my Starlink need?
- ResMed: Power consumption of Air10 devices
- The figures come from the six published sources above. Where they disagree, the chart shows the range and the note under the appliance says who gives what.
- Starting watts are the total draw at start-up as published by the source. For the DTE guide, which gives a starting factor, the chart multiplies running watts by that factor.
- 3 figures are our own estimate and are marked as such: electric kettle, wi-fi router, 12v compressor fridge.
- The example day is our assumption of typical use, not a measurement. Change the hours in your list to match your own.
- The stations shown under an appliance come from our comparison chart: those in stock whose rated output and surge cover the appliance, lowest price first.
- These are reference values. The nameplate of your appliance, or a watt meter, always wins.
Sources read on November 16, 2026.