Anker SOLIX F3800 Plus vs S5000: 3,840Wh vs 5,024Wh, 6,000W vs 4,500W

2 reader comments
Anker SOLIX F3800 Plus portable power station

F3800 Plus

$2,599.99
Sold out at Anker US
  • you run more than 4,500W at once
  • you need 120V and 240V together
  • you use Anker’s Home Power Panel
No BackupPowerHub review yet
VS
Anker SOLIX S5000 portable power station

S5000

$2,499.99
In stock
  • you want 5,024Wh in one box
  • you’ll move it: 97 lb, 38.6 lb less
  • you charge from a 240V outlet
Read our S5000 review

Prices and stock checked by our price engine on November 5, 2026 at 4:31 AM EST. Each product is rechecked several times a day; the time refreshes when you load the page.

Pick by your biggest load, not by the battery: the S5000 holds more, the F3800 Plus pushes harder.

The Anker SOLIX S5000 stores 5,024Wh, delivers 4,500W at 120V or 240V, charges from a 240V outlet at up to 4,500W and switches to battery in 10ms, at 97 lb. The Anker SOLIX F3800 Plus stores 3,840Wh and delivers 6,000W at 120V and 240V at once, takes 3,200W of solar, works with Anker’s Home Power Panel and weighs 135.6 lb. Both have a TT-30R and an L14-30R, and neither has a NEMA 14-50. If your loads stay under 4,500W, the F3800 Plus’s bigger inverter buys you nothing.

Below: every difference with numbers, a 20-second calculator for your own gear, eight modeled situations, and what published tests found on each.

Quick answer

Two 240V Anker stations on wheels, both with a TT-30R and an L14-30R. The S5000 adds 1,184Wh, charges from a 240V outlet at 4,500W and switches in 10ms, in a box 38.6 lb lighter. The F3800 Plus delivers 6,000W instead of 4,500W, at 120V and 240V at once, takes 200W more solar and works with Anker’s Home Power Panel.

Pick the F3800 Plus if$2,599.99
  • you run more than 4,500W
  • you need 120V and 240V at once
  • you want the Home Power Panel
Pick the S5000 if$2,499.99
  • you want 5,024Wh per box
  • you’ll move it: 97 lb
  • you charge from 240V at 4,500W
Price today$2,599.99$2,499.99
Capacity3,840Wh to 26.9kWh5,024Wh to 30.1kWh
AC output6,000W 120V and 240V at once4,500W 120V or 240V
Weight135.6 lb97 lb
F3800 PlusS5000
Bottom line: pick the S5000 if your loads stay under 4,500W: it holds 1,184Wh more, weighs 38.6 lb less, charges from a 240V outlet and switches in 10ms. Pick the F3800 Plus if you run big 240V loads, need 120V and 240V at the same time, or want Anker’s Home Power Panel and Storm Guard.
01 · Differences

The five differences that decide it

Both are Anker 240V stations with LFP cells, wheels, a TT-30R for an RV cord, an L14-30R for a transfer switch, expansion batteries and 5 years of warranty. Neither has a NEMA 14-50. These five gaps decide it.

CapacityLFP
F3800 Plus
3,840Wh
to 26.9kWh with six BP3800
S5000
5,024Wh
to 30.1kWh with five BP5000
S5000
AC outputcontinuous
F3800 Plus
6,000W
120V and 240V at once
S5000
4,500W
120V or 240V, not both at once
F3800 Plus
Weightlighter is better
F3800 Plus
135.6 lb
27.6 × 15.3 × 15.6 in
S5000
97 lb
10.6 × 22.0 × 15.2 in
S5000
240V charging
F3800 Plus
3,300W from a generator
Generator Input Adapter; 120V AC input
S5000
4,500W from an outlet
full in 99 min, per Anker
S5000
Home integration
F3800 Plus
Home Power Panel
also Double Power Hub, Transfer Switch
S5000
Transfer switch or inlet box
not the Home Power Panel
F3800 Plus
Your priorityBetter fit
Loads between 4,500 and 6,000WF3800 Plus
120V and 240V loads at the same timeF3800 Plus
Anker’s Home Power Panel or Storm Guard with itF3800 Plus
Most battery in one box, least weightS5000
Charging from a 240V outlet without a generatorS5000
PC or CPAP on UPSS5000
TT-30R and L14-30R, no 14-50 on eitherTie
TakeawayThe F3800 Plus is the stronger split-phase inverter for a home panel; the S5000 is the bigger, lighter battery that charges from any 240V outlet.
02 · Your setup

Will it run your setup? Check in 20 seconds

1Pick your situation
2Your load
0 Wh/day · peak 0 W
3Your power
1200 W
5 h
4How long each one lasts on a full battery
F3800 Plus
–
S5000
–
Everything on at once
F3800 Plus
0 W of 6,000 W normal
S5000
0 W of 4,500 W normal · 6,000 W SurgePad
Normal outputSurgePad: heating loads only

Estimates use 85% usable capacity and 70% of rated solar output. Real results vary with temperature, inverter load, shade and appliance cycling. Fridge and freezer watts are daily averages and do not include compressor startup surges.

Runtime by appliance, one at a time

Simple energy estimates, not measured runtimes. About 3,264Wh usable on the F3800 Plus and 4,270Wh on the S5000: on the same appliance, the S5000 runs about 31% longer.

Runtime verdict

Appliance for appliance, the S5000 lasts 31% longer than the F3800 Plus.

Same appliance, same watts: the gap is always the size of the battery.
KitchenF3800 PlusS5000
Full-size fridge60W average, about 1.4kWh a day
2.3days
3days
Chest freezer30W average
4.5days
5.9days
Microwave1,100W while running
3hours
3.9hours
Coffee maker1,000W while brewing
3.3hours
4.3hours
Home and officeF3800 PlusS5000
Wi-Fi router12W
11.3days
14.8days
55-inch TV100W
33hours
43hours
Laptop45W
3days
4days
LED lights, 5 bulbs45W
3days
4days
Space heater, high1,500W
2.2hours
2.8hours
Well pump, 1/2 hp1,000W while running; 240V pumps run from the L14-30R on both
3.3hours
4.3hours
Window AC, 8,000 BTU650W while the compressor runs; ESS News ran a portable AC at about 1kW on the S5000
5hours
6.6hours
Medical and sleepF3800 PlusS5000
CPAP, no humidifier40W
3.4days
4.4days
CPAP with humidifier75W
44hours
2.4days
Outdoors and vehicleF3800 PlusS5000
12V compressor fridge45W average; 12V car socket on the F3800 Plus, no 12V output on the S5000
3days
4days
Starlink dish75W, standard kit
44hours
2.4days
Circular saw1,400W while cutting; starts higher
2.3hours
3.1hours
Need longer? Both take extra batteries: the F3800 Plus goes up to 26,880Wh with 6 extra batteries, the S5000 up to 30,144Wh with 5 extra batteries.
Runtime = capacity × 0.85 ÷ watts, for that appliance alone. Loads above 4,500W won’t run on the S5000; above 6,000W, on neither. Anker rates the S5000’s standby draw at 8.8W; PCMag saw about 30 to 40W of background draw on the F3800 Plus while operating. Figures are without expansion batteries.
03 · Money

Get our Black Friday alerts for Anker SOLIX

We track live prices on 40+ models from Jackery, EcoFlow, BLUETTI and Anker SOLIX. When a deal beats the lowest price we've recorded, you'll hear from us. During Black Friday week, one short recap a day at most.

Brands I'm watching (optional)

Unsubscribe in one click. We may earn a commission when you buy through our links, at no extra cost to you. Privacy Policy

The price gap, in numbers

Price verdict, today

The Anker SOLIX S5000 costs $100 less than the Anker SOLIX F3800 Plus and still holds 1,184Wh more.

Prices refresh daily from Anker US.
F3800 Plus $2,599.99S5000 $2,499.99
+$100
F3800 PlusS5000
Price per Wh today
$0.68F3800 Plus (3,840Wh)
$0.50LowerS5000 (5,024Wh)
With one extra battery
F3800 Plus + one BP3800 (7,680Wh)$4,399.98
S5000 + one BP5000 (10,048Wh)BP5000 sold separately

Batteries don’t cross over: the F3800 Plus takes BP3800 only, the S5000 BP5000 only. Anker rates the F3800 Plus at 3,000+ cycles and the S5000 at 6,000, both to 80%. What each price buys is different: 6,000W at 120V and 240V at once and the Home Power Panel on one side, 1,184Wh more, 38.6 lb less and 240V wall charging on the other.

TakeawayCompare what each price buys: inverter power and panel integration, or battery, weight and 240V charging.
04 · Situations

Eight modeled situations, worked out

Same formula as the calculator above, with no expansion battery. The S5000 holds 1,184Wh more, so it runs longer on the same load; the F3800 Plus wins when the load is big or mixes 120V and 240V. The fridge averages 60W, about 525kWh a year, in the range printed on typical EnergyGuide labels; that average does not include compressor startup surges.

24-hour outage, essentials only

Fridge + Wi-Fi router + phones and a laptop + 5 LED bulbs: about 2,190Wh a day (the calculator’s Power outage preset)
F3800 Plus35.8 h
S500046.8 h

The S5000 runs about 11 hours longer. ESS News ran a large fridge plus phones for 61.5 hours on an S5000 during a real PG&E shutoff. PCMag ran a full-size fridge about 63 hours on an F3800 Plus, with one expansion battery.

Several big 240V loads at once

Well pump, electric range burner and a heater running together: about 5,000W
F3800 Plus (6,000W)Runs it
S5000 (4,500W)Overloads

Only the F3800 Plus has the headroom. The S5000 stops at 4,500W, and its guide says it delivers 120V or 240V, not both at once; the F3800 Plus serves both together. Under 4,500W on one voltage, both do the job.

Recharging at 240V

From empty, with a 240V source
F3800 Plus (generator, 3,300W)about 1.2 h
S5000 (outlet, 4,500W)99 min

The S5000 takes up to 4,500W from a 240V outlet or generator through its AC input, with Anker’s 240V Fast Charging Cable, sold in a separate bundle. The F3800 Plus’s AC input is 120V; 240V goes in through its generator port with the Generator Input Adapter, at 3,300W on one unit or 6,000W with an expansion battery.

An RV with a 30A inlet

A 30A RV shore cord
F3800 PlusTT-30R, 3,000W
S5000TT-30R, 3,600W

Both take a 30A RV cord directly. The S5000’s TT-30R is rated 3,600W, the F3800 Plus’s 3,000W. Ground the S5000 first: Anker says it has a floating neutral. Only the F3800 Plus has a 12V socket for 12V gear.

Charging an EV at 240V

A Level 2 mobile charger set below the station’s limit
F3800 Plus6,000W, L14-30
S50004,500W, L14-30

Neither has a NEMA 14-50, so a 14-50 mobile charger needs an L14-30 adapter on both. The F3800 Plus delivers more power, the S5000 more energy: 5,024Wh is still a top-up, not a full charge.

Refill from solar, each at its maximum

Hours of full sun to refill from empty, at 70% of panel rating: 3,200W on the F3800 Plus, 3,000W on the S5000
F3800 Plus (3,200W)1.7 h
S5000 (3,000W)2.4 h

The F3800 Plus refills sooner: more input and a smaller battery. Both take high-voltage strings up to 165V; the S5000 splits its input into 2,000W at 16 to 165V and 1,000W at 11 to 60V. ESS News saw 680W from two 400W panels on the S5000 on a sunny October day.

Home office through an outage

Desktop PC + monitor 8 h + router and modem all day: about 1,850Wh a day (the calculator’s Home office UPS preset)
F3800 Plus42.3 h
S500055.4 h

Both carry about two workdays. The S5000 switches in 10ms, and Bob Vila’s desktop PC kept running when it was unplugged from the wall. The F3800 Plus switches in 20ms on its three left 120V outlets, plugged into a 120V outlet, with a 1,440W bypass limit; PCMag’s workstation rode through simulated outages without a reboot.

Moving it

Rolling it to the garage or up a step
F3800 Plus135.6 lb
S500097 lb

Both roll on wheels. AppleInsider found small bumps can stop the F3800 Plus’s wheels; ESS News found the S5000 tippy on grass. Plan on two people for stairs with either.

05 · More differences

Nine more differences, the spec sheet and the box

Smaller gaps that rarely decide the purchase, then the full specifications and what ships in the box.

Solar inputmax
F3800 Plus
3,200W
2 inputs, 11 to 165V, 17A
S5000
3,000W
2,000W at 16 to 165V + 1,000W at 11 to 60V
F3800 Plus
Max expansionper unit
F3800 Plus
26.9kWh
six BP3800; 53.8kWh with two units
S5000
30.1kWh
five BP5000
S5000
UPS switchoverfaster is better
F3800 Plus
20ms
3 left outlets, on a 120V outlet
S5000
10ms
standby UPS
S5000
TT-30R120V, 30A RV plug
F3800 Plus
3,000W
S5000
3,600W
ground it first: floating neutral
S5000
Surge
F3800 Plus
Not published
Anker lists none for the Plus
S5000
8,000W for 1 s
SurgePad 6,000W for heating loads
S5000
12V output
F3800 Plus
Car socket, 12V 10A
S5000
None
ESS News flagged it
F3800 Plus
Car charging
F3800 Plus
Not listed
absent from the Plus user guide
S5000
800W Alternator Charger
on the low-voltage input
S5000
Standby draw
F3800 Plus
About 30 to 40W
background draw while operating, PCMag
S5000
8.8W
Anker; ESS News saw about 10W
S5000
Rated cycles
F3800 Plus
3,000+ to 80%
S5000
6,000 to 80%
10,000 to 60%
S5000

F3800 Plus and S5000 weight, dimensions and full specifications

Weight: 135.6 lb for the Anker SOLIX F3800 Plus (user guide; Anker’s page says 136.7 lb) and 97 lb for the Anker SOLIX S5000. Dimensions: 27.6 × 15.3 × 15.6 in and 10.6 × 22.0 × 15.2 in, wheels included. Everything else is in the sheet below.

Anker SOLIX F3800 Plus and S5000 full specifications
Every published figure for both units, grouped. Green marks the better value.
SpecF3800 PlusS5000
Battery
Rated capacity
3,840Wh (51.2V, 75Ah)
5,024Wh314Ah LFP cells
Chemistry
LFP
Rated cycles
3,000+ to 80%
6,000 to 80%10,000 to 60%
Expansion
Up to 6 × BP3800, 26.9kWh53.8kWh and 12,000W with two units
Up to 5 × BP5000, 30.1kWhBP3800 and BP3000 don’t fit
Output
AC output
6,000W, 120V and 240V at once
4,500W, 120V or 240Vnot both at once
Surge
Not published
8,000W for 1 s; SurgePad 6,000W
120V outlets
6 × NEMA 5-20R2,400W per group of three
NEMA 5-20R, 2,400Wfour per ESS News; Anker doesn’t state the count
Big outlets
TT-30R (3,000W) + L14-30R (6,000W)
TT-30R (3,600W) + L14-30R (4,500W)
NEMA 14-50
None
USB
USB-A 12W, USB-C 100W
USB-A 12W, USB-C 15W + 100W
12V DC
Car socket, 12V 10A
None
UPS
20ms on the 3 left outlets
10ms
Inputs
AC charging
1,800W at 120V1,440W in bypass
1,800W at 120V, 12A after about 3 h; 4,500W at 240V
240V generator
3,300W, 6,000W with a batteryGenerator Input Adapter required
Through the AC input, up to 4,500WSmart Generator 5500 auto start
Solar
3,200W, 2 inputs, 11 to 165V, 17A
3,000W: 2,000W at 16 to 165V + 1,000W at 11 to 60V
Car
Not listed
800W Alternator Charger, on the low-voltage input
Physical
Dimensions
27.6 × 15.3 × 15.6 in
10.6 × 22.0 × 15.2 in
Weight
135.6 lb (61.5 kg)136.7 lb on Anker’s page
97 lb
Wheels
Yes, with a handle
Ingress
Not rated
Environment
Charging
32°F to 104°F
Discharging
−4°F to 104°F
Software
App
Anker app, Wi-Fi + Bluetooth
Home integration
Home Power Panel (6,000W in), Double Power Hub, Transfer Switch
Transfer switch or inlet box on the L14-30Rnot the Home Power Panel
Storm Guard
With the Home Power Panel
Built in
Warranty
Warranty
5 years
Model
A1790P
AS510
Sources: the Anker US F3800 Plus page and its user guide (A1790P), the Anker US S5000 page, launch page and user guide (AS510), read on October 30, November 1 and November 2, 2026. Reviewer figures are credited in the reports section.

What’s in the box

F3800 Plus

  • F3800 Plus power station3,840Wh, 135.6 lb
  • AC charging cable
  • Solar charging cables × 2
  • User manual
  • Generator Input Adapter sold separatelyneeded for 240V generator charging

S5000

  • S5000 power station5,024Wh, 97 lb
  • AC charging cable
  • User guide
  • Solar cables sold separately

F3800 Plus: Anker US page and user guide. S5000: Anker US page and user guide; the 240V Fast Charging Cable comes in a separate bundle.

06 · Charging

How fast each one refills

Shorter bar, faster refill. Each row is scaled to its slower unit.

Wall outlet, 120V, full
F3800 Plus
about 2.1 h1,800W, our estimate
S5000
about 3.5 hBob Vila measured; 1,800W, then 12A after about 3 h
240V source, full
F3800 Plus
about 1.2 h3,300W from a generator, with the adapter; our estimate
S5000
99 min4,500W from a 240V outlet, Anker
Solar at max input, full
F3800 Plus
about 1.7 h3,200W at 70%; Anker says 1.5 h
S5000
about 2.4 h3,000W at 70%

F3800 Plus: 6,000W through the Home Power Panel or a generator, with an expansion batteryS5000: each BP5000 adds 3,200W of charging, up to 12,000W; ESS News saw 1.79kW for 2 h 49 at 120V

Our times divide capacity by input power, with solar at 70% of panel rating; real charging slows near full.

TakeawayFrom a 120V outlet or solar the F3800 Plus is full first; at 240V the S5000 needs only an outlet and a cable, the F3800 Plus a generator and its adapter.
07 · Ports

Every port, side by side

F3800 Plus

Outputs
AC × 6 NEMA 5-20R, 20ANEMA 14-50 noneL14-30R 240V, 6,000WTT-30R 120V, 3,000WUSB-A and USB-C 12W / 100W12V socket 10A
Inputs
AC in 1,800WSolar × 2 3,200W, 11 to 165VHome Power Panel / generator port 6,000W inExpansion port BP3800

S5000

Outputs
AC NEMA 5-20R, 2,400WNEMA 14-50 noneL14-30R 240V, 4,500WTT-30R 120V, 3,600WUSB-A and USB-C 12W / 15W + 100W12V socket none
Inputs
AC in 1,800W at 120V, 4,500W at 240VHigh-PV + Low-PV 2,000W + 1,000WExpansion port BP5000

Practical consequence: the same big plugs on both, a TT-30R for a 30A RV cord and an L14-30R for a transfer switch, and no NEMA 14-50 on either. The F3800 Plus has six 20A outlets, a 12V socket and a Home Power Panel port; the S5000 takes 240V straight into its AC input.

08 · Noise

Noise: F3800 Plus vs S5000

Noise verdict

Both are quiet at light loads. Anker rates the Anker SOLIX S5000 under 30dB at 2,000W; AppleInsider measured the Anker SOLIX F3800 Plus at up to 60dB under a heavy load.

Anker publishes no rating for the F3800 Plus, and AppleInsider gives no distance.
F3800 PlusS5000
Is it quiet at low load?light household loads
Whisper-quietuntil heavily loaded (AppleInsider)
Nearly silentportable AC (Bob Vila)
How loud at 2,000W?brand rating
Not given
Under 30dBAnker lab, 1 m
How loud under a heavy load?what reviewers measured or heard
Up to 60dBAppleInsider, distance not stated
Noticeable humrising load (Bob Vila)
Is it quiet while charging?from the wall
Not measured
Very quietESS News
Every figure we found, with its source
30dBwhisper40dBlibrary60dBconversation
F3800 Plus
Heavy loadAppleInsider, distance not stated
≤60dB

What reviewers heard: Whisper-quiet until heavily loaded; then the fans may reach 60 decibels (AppleInsider).

S5000
2,000WAnker lab, 1 m
≤30dB

What reviewers heard: Charging very quiet, even quieter than the S2000 (ESS News); nearly silent running a portable AC, but the fans hum noticeably as the load rises (Bob Vila).

Measured by a tester Brand figure

For quiet nights
  • Lower the AC charging power in the Anker app when the unit sits in a living space overnight.
09 · Temperatures

Cold and heat: F3800 Plus vs S5000

Weather verdict

The Anker SOLIX F3800 Plus and the Anker SOLIX S5000 share the same limits: charging from 32°F to 104°F, running from −4°F to 104°F. Neither has a water rating.

Figures from the F3800 Plus (A1790P) and S5000 (AS510) user guides.
F3800 PlusS5000
Can it charge below freezing?
Nofrom 32°F
Nofrom 32°F
Coldest it can run
−4°F
−4°F
Hottest it can run
104°F
104°F
Water and dust rating
Nonekeep it under cover
Nonekeep it under cover
-4°F-20°C32°F0°C77°F25°C122°F50°C
Chargingsame on both
Both
32°F104°F
Runningsame on both
Both
-4°F104°F
Freezing, 32°F
Where to keep it
  • In a garage in winter, charge either one indoors or wait for the battery to warm up: neither charges below 32°F.
10 · Software

App, UPS and smart features

Smart features verdict

The Anker SOLIX F3800 Plus delivers 120V and 240V at once and works with Anker’s Home Power Panel. The Anker SOLIX S5000 switches faster, 10ms against 20ms, and adds Storm Guard on its own, Smart Generator 5500 auto start and SurgePad.

Both use the Anker app over Wi-Fi and Bluetooth.
F3800 PlusS5000
Can it deliver 120V and 240V at once?Differs
YesBoth at once
NoOne or the other
Can it start a generator by itself?Differs
Not listedNot listed by Anker
YesSmart Generator 5500
Can it run a heater or kettle above its rating?Differs
Not listedNot listed by Anker
YesSurgePad, up to 6,000W
Does it work as a UPS?
Yes20ms, three left outlets
Yes10ms switchover
Does it connect to a home panel?
YesHome Power Panel, Transfer Switch
PartlyTransfer switch or inlet box
Does it prepare for storms?
YesStorm Guard, with the Home Power Panel
YesStorm Guard
Can you add a battery later?
YesSix BP3800, up to 26.9kWh
YesFive BP5000, up to 30.1kWh
UPS switchover, in milliseconds
F3800 Plus 20msS5000 10ms
0ms30ms

Green zone: a switch under about 16ms, which most desktop PCs ride through without restarting.

Can it deliver 120V and 240V at once? The Anker SOLIX F3800 Plus delivers 120V and 240V at the same time, except its 240V while it charges from a 120V outlet; the Anker SOLIX S5000 delivers one or the other, never both at once, per its guide.

Can it start a generator by itself? The Anker SOLIX S5000’s user guide lists automatic start and stop of Anker’s Smart Generator 5500 at set battery levels. The Anker SOLIX F3800 Plus charges from a 240V generator at 3,300W through the Generator Input Adapter, with no auto start listed.

Can it run a heater or kettle above its rating? The Anker SOLIX S5000’s SurgePad runs heating loads up to 6,000W, not in bypass mode; Anker lists no such mode for the Anker SOLIX F3800 Plus, whose continuous 6,000W is already that high.

Does it work as a UPS? The Anker SOLIX S5000 switches in 10ms, and Bob Vila’s PC kept running. The Anker SOLIX F3800 Plus switches in 20ms on its three left 120V outlets, plugged into a 120V outlet, with a 1,440W bypass limit.

Does it connect to a home panel? The Anker SOLIX F3800 Plus works with Anker’s Home Power Panel (6,000W in), Double Power Hub and Transfer Switch. The Anker SOLIX S5000 feeds a compatible transfer switch or power inlet box from its L14-30R, but not the Home Power Panel or the E10 system.

Does it prepare for storms? Both have Storm Guard. On the Anker SOLIX F3800 Plus it needs the Home Power Panel; the Anker SOLIX S5000’s uses local weather alerts on its own to recharge at full speed before severe weather.

Can you add a battery later? Both grow: up to six BP3800 take the Anker SOLIX F3800 Plus to 26.9kWh, up to five BP5000 take the Anker SOLIX S5000 to 30.1kWh. The batteries don’t cross over.

11 · Warranty

Warranty and support

Warranty verdict

Anker lists both the Anker SOLIX F3800 Plus and the Anker SOLIX S5000 at 5 years. For the F3800 Plus, Anker’s registration page says registering activates that protection; we found no such condition for the S5000.

Same term. The S5000 is rated for twice the cycles to 80%.
Years covered from purchase
F3800 Plus
S5000
BuyYear 1Year 2Year 3Year 4Year 5
F3800 Plus5 years from purchase once registered with Anker; Anker does not state the term without it.
S5000Covered for 5 years from purchase.

Subject to each brand’s warranty terms and eligibility.

F3800 PlusS5000
Rated cycles
3,000 to 80%
6,000 to 80%
At one full cycle a day
about 8 years
about 16 years

Anker rates the F3800 Plus at 3,000+ cycles and the S5000 at 6,000, both to 80% (10,000 to 60% on the S5000): about 8 and 16 years at one full cycle a day. The F3800 Plus page also mentions 4,000 cycles in a marketing line; we use its spec table. Calendar aging and heat also reduce capacity.

Before you buy
  • If you choose the F3800 Plus, register it with Anker: its registration page says that is what activates the 5 years.
  • The S5000 needs no step we could find: Anker states no S5000-specific registration condition.
Checked on Anker’s US F3800 Plus, S5000 and registration pages, and the S5000 launch page, October and November 2026.
12 · Reviewers

What reviewers report

We have not lab-tested these two units. Here is what 6 published reviews found, with the source, author and date for each point. Reviews of UK and EU units are flagged: those models charge from 230V outlets and have different sockets, so their charge times and outlet findings don’t carry over to US units.

F3800 Plus: PCMag (May 2026), How-To Geek (March 2025), AppleInsider (August 2025), Gear Diary (April 2025)S5000: ESS News (pv magazine group) (October 2026), Bob Vila (October 2026)

Usable capacity

  • F3800 PlusReviewer With an expansion battery it ran a full-size fridge about 63 hours, delivering roughly 4,248Wh of AC. PCMag, Michael Lydick, May 2026
  • F3800 PlusReviewer Running AC, fridge, lights and TV off-grid, the display estimated about two hours. Gear Diary, Travis Ehrlich, April 2025
  • S5000Reviewer On a full discharge the app reported 4.87kWh delivered, about 97% of the 5,024Wh nameplate; output was not independently metered. ESS News (pv magazine group), Andrew Riha, October 2026
  • S5000Reviewer During a real PG&E shutoff it ran a large fridge plus phones for 61.5 hours, from 100% down to 18%. ESS News (pv magazine group), Andrew Riha, October 2026
  • S5000Reviewer Running a home refrigerator until the battery was empty, it lasted around 86 hours, matching Anker’s claim. Bob Vila, Paul Rankin, October 2026

Charging

  • F3800 PlusReviewer Refilling from empty took roughly 9,000Wh from the wall, about 85% round-trip efficiency. PCMag, Michael Lydick, May 2026
  • F3800 PlusReviewer Solar input rises to 3,200W and 165V, so third-party panels can run in series. How-To Geek, Bertel King, March 2025
  • S5000Reviewer Charging at the 1,800W setting from 120V, wall draw held near 1.79kW for 2 h 49 min, then dropped to about 1.43kW for the last 50 minutes. ESS News (pv magazine group), Andrew Riha, October 2026
  • S5000Reviewer A full charge pulled 6.24kWh from the wall, giving roughly a 78% round trip based on the app’s discharge reading. ESS News (pv magazine group), Andrew Riha, October 2026
  • S5000Reviewer At the 1,000W setting the charge took 65% longer but used only 1.7% less wall energy. ESS News (pv magazine group), Andrew Riha, October 2026

Noise and heat

  • F3800 PlusReviewer Whisper-quiet until heavily loaded; then fans may reach 60 decibels (no distance given). AppleInsider, Wesley Hilliard, August 2025
  • S5000Reviewer Charging was very quiet, even quieter than the smaller S2000; the reviewer did not measure decibels. ESS News (pv magazine group), Andrew Riha, October 2026
  • S5000Reviewer Nearly silent running a portable AC, but the cooling fans hum noticeably as the load rises. Bob Vila, Paul Rankin, October 2026

UPS and output

  • F3800 PlusReviewer Kept a desktop workstation running through simulated outages without a reboot. PCMag, Michael Lydick, May 2026
  • F3800 PlusReviewer The 240V port was replaced by a 120V TT-30R, a loss for users of a 50A home inlet. How-To Geek, Bertel King, March 2025
  • S5000Reviewer A portable air conditioner ran for more than four hours at about 1kW with no problem. ESS News (pv magazine group), Andrew Riha, October 2026
  • S5000Reviewer There is no 12V DC output, which RV and van setups often expect. ESS News (pv magazine group), Andrew Riha, October 2026
  • S5000Reviewer Unplugging the S5000 from the wall while it powered a desktop PC caused no interruption. Bob Vila, Paul Rankin, October 2026

Daily use and issues

  • F3800 PlusReviewer Background draw averages about 30 to 40W while operating, which adds up over days. PCMag, Michael Lydick, May 2026
  • F3800 PlusReviewer The original F3800 uses over 1kWh a day idle; the Plus draws slightly less, maybe an extra hour or two. How-To Geek, Bertel King, March 2025
  • F3800 PlusReviewer Weighs 136.7 lb; small bumps can stop the wheels. AppleInsider, Wesley Hilliard, August 2025
  • S5000Reviewer With 120V output on and nothing plugged in, it lost 5% charge in 24 hours, about 10W, in line with Anker’s 8.8W idle rating. ESS News (pv magazine group), Andrew Riha, October 2026
  • S5000Reviewer Plugged in and full, it kept drawing about 7W from the wall, roughly 60kWh a year. ESS News (pv magazine group), Andrew Riha, October 2026
  • S5000Reviewer The E10 Smart Generator cable would not fully seat in this pre-release unit, so generator charging was not tested. ESS News (pv magazine group), Andrew Riha, October 2026
TakeawayPCMag measured long fridge runtimes and a clean UPS switchover on the F3800 Plus and flagged its background draw; the two S5000 tests so far found long real outage runtimes and quiet charging, with no 12V output and a tippy base on grass.
13 · Practical limits

Practical limits before you buy

  1. Neither has a NEMA 14-50. A 50A RV cord or a 14-50 EV charger needs an L14-30 adapter on both.
  2. The S5000 stops at 4,500W, and delivers 120V or 240V, not both at once.
  3. The F3800 Plus can’t charge at 240V through its AC input. That input is 120V, 1,800W; 240V charging goes through its generator port with the Generator Input Adapter.
  4. The S5000’s 240V charging uses Anker’s 240V Fast Charging Cable. On November 1, 2026, Anker’s page listed that cable in a separate S5000 bundle.
  5. The S5000 doesn’t work with Anker’s Home Power Panel, and its batteries don’t fit the F3800 Plus: BP3800 and BP5000 don’t cross over.
  6. The S5000 has no 12V output. RV and van setups need a converter; the F3800 Plus has a 12V car socket.
  7. The F3800 Plus’s Storm Guard needs the Home Power Panel; the S5000’s works on its own.
  8. Both are heavy. 135.6 lb and 97 lb: wheels help on flat floors, plan on two people for stairs.
  9. F3800 Plus, per its US documentation: The 240V output cannot be used while the unit charges from 120V AC.
  10. F3800 Plus, per its US documentation: On a 120V wall outlet only the TT-30R (no UPS) and the 3 leftmost NEMA 5-20R (UPS) work, with a 1,440W bypass limit.
  11. F3800 Plus, per its US documentation: Generator charging: generator must output pure sine wave with THD under 5%; 6,000W 240V bypass needs the Generator Adapter, single unit only.
  12. F3800 Plus, per its US documentation: Storm Guard requires the Home Power Panel.
14 · FAQ

Frequently asked questions

What is the difference between the Anker S5000 and the F3800 Plus?

The S5000 stores 5,024Wh, delivers 4,500W at 120V or 240V, charges from a 240V outlet at 4,500W, switches in 10ms and weighs 97 lb. The F3800 Plus stores 3,840Wh, delivers 6,000W at 120V and 240V at once, takes 3,200W of solar, works with the Home Power Panel and weighs 135.6 lb.

Which is cheaper?

The Anker SOLIX S5000 costs $100 less today: $2,499.99, against $2,599.99 for the Anker SOLIX F3800 Plus. Prices refresh daily; the price section above has the full breakdown.

Which has more power?

The F3800 Plus: 6,000W at 120V and 240V at once. The S5000 delivers 4,500W, at 120V or 240V but not both at the same time, with an 8,000W surge for one second; Anker publishes no surge figure for the F3800 Plus.

Which lasts longer in an outage?

The S5000: 5,024Wh against 3,840Wh, about 31% more runtime on the same load, or about 47 hours against 36 on our essentials preset.

Which charges from a 240V outlet?

The S5000, through its AC input at up to 4,500W with Anker’s 240V Fast Charging Cable, full in 99 minutes per Anker. The F3800 Plus charges at 240V from a generator through its Generator Input Adapter: 3,300W on one unit, 6,000W with an expansion battery.

Does either have a NEMA 14-50?

No. Both have a TT-30R and an L14-30R. A 14-50 EV charger or a 50A RV cord needs an L14-30 adapter on either one.

Which is better for an RV?

Both take a 30A cord on their TT-30R: 3,600W on the S5000, 3,000W on the F3800 Plus. Only the F3800 Plus has a 12V socket; ground the S5000 first, since Anker says it has a floating neutral.

Can I use BP3800 batteries with the S5000?

No. The S5000 takes BP5000 batteries only, up to five for 30.1kWh. The F3800 Plus takes up to six BP3800, for 26.9kWh.

Which works with Anker’s Home Power Panel?

The F3800 Plus, with up to 6,000W in, plus Storm Guard. The S5000 isn’t compatible; it feeds a transfer switch or power inlet box from its L14-30R.

I own the original F3800. Where does it fit?

Our F3800 vs S5000 comparison covers it; the F3800 Plus keeps its 3,840Wh and 6,000W, with a TT-30R in place of the NEMA 14-50.

15 · Related 16 · Method

How we compared and sources

Research-based comparison. We have not physically tested these two units. Specs come from Anker US documentation for both and their user guides; usage observations are attributed to named reviewers. Prices and availability are checked by our price engine; specs were read on October 30, November 1 and November 2, 2026.

  • Specs: Anker US, F3800 Plus and its user guide (A1790P), and Anker US, S5000 with its user guide (AS510), read on October 30, November 1 and November 2, 2026.
  • Anker’s F3800 Plus page lists 136.7 lb and its user guide 135.6 lb; we use the guide. The same page gives 3,000+ cycles in its specs and 4,000 cycles in a marketing line; we use the specs. It also calls the unit compatible with 240V wall outlets, while its AC input is rated 120V: we describe 240V charging through the generator port, as its FAQ does.
  • S5000 outlet count: ESS News; Anker doesn’t state the number of NEMA 5-20R outlets. Anker’s S5000 page reuses some S2000 text; we used its spec table, FAQ and user guide only.
  • Reviewer reports on the F3800 Plus: PCMag, Michael Lydick, May 2026, How-To Geek, Bertel King, March 2025, AppleInsider, Wesley Hilliard, August 2025, Gear Diary, Travis Ehrlich, April 2025; on the S5000: ESS News (pv magazine group), Andrew Riha, October 2026, Bob Vila, Paul Rankin, October 2026.
  • Runtime = capacity × 0.85 ÷ watts. Solar harvest = min(panel watts, max input) × sun hours × 0.70.

Looking at other models? Browse all power station comparisons, or pick any two models on the hub and we point you to the right duel.

Originally published: November 4, 2026

Reader comments 2

  1. Interested in the Anker 3800 plus with one extra battery to use as a backup to connect thru a outside gas generator inlet box-I want to get back-up solar panels also-can you tell me what additional cables I need to charge the unit from the gas generator and what solar cables-and anything thing else I might need.

    Reply
    • Hi Ken, good setup. You’ll be making three separate connections, so here’s what each one needs.

      Station to your inlet box. Use a 30A, 4-prong generator cord: the L14-30P end goes into the station’s L14-30R outlet, and the L14-30R end goes into the inlet box. This assumes a 30A L14-30 inlet. A 50A inlet needs a different cord. The cord isn’t included.

      The inlet box must feed an interlock or a transfer switch, so your home is isolated from the grid. Anker also asks you to confirm that the neutral and ground are properly connected at the inlet box, so have an electrician check that part.

      Gas generator to the station. You can’t charge through the inlet box. You need Anker’s Generator Input Adapter, which is sold separately. It plugs into the generator’s 240V L14-30 outlet and into the station’s Home Power Panel/generator port.

      Charging runs at up to 6,000W with your expansion battery, compared with 3,300W for the station alone. The generator must put out clean pure sine wave power (under 5% THD), so check its spec sheet first. While it’s connected, the L14-30R and TT-30R stay available, but the 20A household outlets on the station are off. Keep the generator outdoors, well away from doors and windows.

      Solar panels. The station has two solar inputs. Each one takes 11 to 165V, 17A and 1,600W, for 3,200W in total. Two solar cables come in the box, so look at those first. If you need another cable for standard MC4 panels, Anker’s High-Voltage Solar Charging Cable goes from the station to MC4, and it’s only about 20 inches long, so plan on MC4 extension cables to reach the panels. Keep each series string under 165V, even on cold days, because going over can damage the port.

      Expansion battery. The BP3800 comes with its own connecting cable, so you don’t need anything extra there.

      If you tell me your generator model and your inlet box amperage, I can confirm that they’ll work together. If the generator is 120V only, the setup is different, so that’s worth checking before you buy. Our Anker transfer switch guide also covers the home connection in more detail.

      Reply

Leave a comment

Questions about your setup are welcome. Your email is never published, and comments are reviewed before they appear.